The DR1900 is perfect for use in the field because it is the lightest and most compact portable spectrophotometer. It also can perform that largest number of tests of any portable instrument. Underneath the rugged exterior, the DR1900 has the largest number--over 220--of the most commonly tested preprogrammed methods already built in. You can also use the easy-to-use interface to create your own methods. Also, it is flexible because you can use the widest range of vial sizes of any other Spectrophotometer
HACH DR1900 PORTABLE SPECTROPHOTOMETER
SPESIFICATIONS
Beam Height | 10 mm |
---|---|
Data Logger | 2000 Measured Values (Result,Date,Time,Sample ID,User ID) |
Dimensions (H x W x D) |
151 mm x 350 mm x 255 mm |
Display | 7" TFT |
Display Resolution | WVGA (800 pix x 480 pix) |
Display Size | 7 inch (17.8 cm) |
Display Type | Colored touch-screen |
Enclosure Rating | IP30 |
Includes |
Adapter "A" for 1" round + Accuvac/1 cm rectangula cuvettes, manual in m 5 languages (GB,D, F,I,E),power supply 100 - 240V ,47-63Hz. |
Interfaces | USB type A (2) ; USB type B |
Ethernet ; RFID module |
|
Light Source | Gas-filled Tungsten (visible) |
Manual Languages | English ; French (CDN) ; Spanish (SA) |
Portuguese (BR) ; Chinese ; Japanese ; Korean |
|
Max. Operating Humidity |
80% |
Max. Storage Humidity | 80% |
Operating Conditions | 10 °C - 40 °C |
Operating Mode | Transmittance (%), Absorbance and Concentration,Scanning |
Optical System | Reference beam, spectral |
Photometric Accuracy | 5 mAbs @ 0.0 - 0.5 Abs |
Photometric Accuracy 2 | 1 % at 0.50 - 2.0 Abs |
Photometric Linearity | < 0.5 % - 2 Abs |
Photometric Linearity 2 | ≤ 0.01 % at >2 Abs with neutral glass at 546 nm |
Photometric Measuring Range |
± 3.0 Abs (wavelength range 340 - 900 nm) |
Power Requirements | With external power supply |
Power Requirements (Hz) | 50/60 Hz |
Power Requirements (Voltage) |
110 - 240 V AC |
Power Supply | Benchtop Power Supply |
Preprogrammed Methods | > 240 |
Sample Cell Compatibility |
Rectangular: 10, 20, 30, 50 mm, 1 inch; round: 13 mm, 16 mm, 1 inch |
Scanning Speed | > 8 nm/S (in steps of 1 nm) |
Specific Technology | RFID for easy method update, sample ID and Certificate of Analysis |
Spectral Bandwidth | 5 nm ± 1 nm |
Storage Conditions | -30 °C to 60 °C |
Stray Light | < 0.1 % T at 340 nm with NaNO2 |
User Interface Languages | Bulgarian, Chinese, Croatian, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Polish, Portuguese - Brazil, Portuguese, |
Russian, Serbian, Slovakian, Slowenian, Spanish, Swedish, Turkish |
|
User Programs | 100 |
Warranty | 12 months |
Wavelength Accuracy | ± 1.5 nm (wavelength range 340 - 900 nm) |
Wavelength Calibration | Automatic |
Wavelength Range | 320 - 1100 nm |
Wavelength Reproducibility |
± 0.1 nm |
Wavelength Resolution | 1 NM |
Wavelength Selection | Automatic, based on method selection |
Weight | 4.2 kg |
DR3900 LABORATORY VIS SPECTROPHOTOMETER
Simplicity throughout: The DR3900 Spectrophotometer provides the simplest way to perform tests for water analysis. Used together with TNTplus™ test kits testing steps are reduced. The potential for human errors is minimized. The system of Spectrophotometer and test kits supports the process optimization of waste water treatment plants and environmental testing.This instrument connects to Claros, Hach's innovative Water Intelligence System, enabling you to seamlessly connect and manage instruments, data, and process – anywhere, anytime. The result is greater confidence in your data and improved efficiency in your operations. To unlock the full potential of Claros, insist on Claros Enabled instruments.
SPESIFICATIONS
Beam Height |
10 mm |
Data Logger |
2000 Measured Values (Result, Date, Time, Sample ID, User ID) |
Dimensions (H x W x D) |
151 mm x 350 mm x 255 mm |
Display |
7" TFT |
Display Resolution |
WVGA (800 pix x 480 pix) |
Display Size |
7 inch (17.8 cm) |
Display Type |
Colored touch-screen |
Enclosure Rating |
IP30 |
Includes |
Adapter "A" for 1" round + Accuvac/1 cm rectangular cuvettes, manual in m 5 languages (GB, D, F, I, E), power supply 100 - 240V, 47 - 63Hz. |
Interfaces |
USB type A (2) ; USB type B Ethernet ; RFID module |
Light Source |
Gas-filled Tungsten (visible) |
Manual Languages |
English ; French (CDN) ; Spanish (SA) Portuguese (BR) ; Chinese ; Japanese ; Korean |
Max. Operating Humidity |
80 % |
Max. Storage Humidity |
80 % |
Operating Conditions |
10 °C - 40 °C |
Operating Mode |
Transmittance (%), Absorbance and Concentration, Scanning |
Optical System |
Reference beam, spectral |
Photometric Accuracy |
5 mAbs @ 0.0 - 0.5 Abs |
Photometric Accuracy 2 |
1 % at 0.50 - 2.0 Abs |
Photometric Linearity |
< 0.5 % - 2 Abs |
Photometric Linearity 2 |
≤ 0.01 % at >2 Abs with neutral glass at 546 nm |
Photometric Measuring Range
|
± 3.0 Abs (wavelength range 340 - 900 nm) |
Power Requirements |
With external power supply |
Power Requirements (Hz) |
50/60 Hz |
Power Requirements (Voltage) |
110 - 240 V AC |
Power Supply |
Benchtop Power Supply |
Preprogrammed Methods |
> 240 |
Sample Cell Compatibility |
Rectangular: 10, 20, 30, 50 mm, 1 inch; round: 13 mm, 16 mm, 1 inch |
Scanning Speed |
> 8 nm/S (in steps of 1 nm) |
Specific Technology |
RFID for easy method update, sample ID and Certificate of Analysis |
Spectral Bandwidth |
5 nm ± 1 nm |
Storage Conditions |
-30 °C to 60 °C |
Stray Light |
< 0.1 % T at 340 nm with NaNO2 |
User Interface Languages |
Bulgarian, Chinese, Croatian, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian,Japanese,Korean,Polish,Portuguese,Brazil,Portuguese, Russian,Serbian,Slovakian,Slowenian,Spanish,Swedish,Turkish |
User Programs |
100 |
Warranty |
12 months |
Wavelength Accuracy |
± 1.5 nm (wavelength range 340 - 900 nm) |
Wavelength Calibration |
Automatic |
Wavelength Range |
320 - 1100 nm |
Wavelength Reproducibility |
± 0.1 nm |
Wavelength Resolution |
1 NM |
Wavelength Selection |
Automatic, based on method selection |
Weight |
4.2 kg |
DR6000 UV VIS SPECTROPHOTOMETER
The DR6000™ is the industry's most advanced laboratory Spectrophotometer for water testing. It offers high-speed wavelength scanning across the UV and Visible Spectrum, and comes with over 250 pre-programmed methods including the most common water and environmental testing methods used today. With optional accessories allowing for high-volume testing via a carousel sample changer, and increased accuracy with a sample delivery system that eliminates optical difference errors, this instrument ensures you are ready to handle your wide-ranging water testing needs
RFID currently available only in US, Anguilla, American Samoa, Australia, Bolivia, Canada, Cayman Islands, Columbia, Dominican Republic, El Salvador, Federated States of Micronesia, Guam, Guatemala, Marshall Islands, New Zealand, Northern Mariana Islands, Palau, Panama, Puerto Rico, and US Virgin Islands. Customers in other countries should order LPV441.99.00002.
SPESIFICATIONS
Data Logger | 5000 data points (result, date, time, sample-ID, user-ID) |
Dimensions (H x W x D) |
215 mm x 500 mm x 460 mm |
Display |
TFT 7 inch WVGA color touch |
Enclosure Rating |
IP20 with closed lid |
Includes |
1x Power Cord (US,EU) ;1x Universal Adapter;1xDust Cover Matched pair of 1 inch glass sample cells Printed multilingual basic user manaul (en,es,fr,ja,ko,pt,zh) |
Interfaces |
USB type A (2), USB type B, Ethernet, RFID module |
Manual Languages |
en, es, fr, ja, ko, pt, zh |
Operating Conditions |
10 - 40 °C, max. 80% relative humidity (non-condensing) |
Operating Mode |
Transmittance (%), absorbance and concentration (wavelength, time) |
Optical System |
Reference beam, spectral |
Photometric Accuracy |
5 mAbs @ 0.0 - 0.5 Abs <1% @ 0.5 - 2.0 Abs @ 546 nm |
Photometric Linearity |
0.005 - 2 Abs ≤ 0.01 at > 2 Abs with neutral glass at 546 nm |
Photometric Measuring Range |
± 3 Abs |
Power Requirements |
100 - 240 V; 50/60 Hz |
Preprogrammed Methods |
> 240 |
Sample Cell Compatibility |
Rectangular: 10, 20, 30, 50 mm, 1 inch; round: 13 mm, 16 mm, 1 inch Optional 100 mm rectangular cell with additional adapter |
Scanning Speed |
900 nm/min (in 1 nm steps) |
Specific Technology |
RFID for easy method update, sample ID and Certificate of Analysis |
Spectral Bandwidth |
2 nm |
Storage Conditions |
-25 to 60 °C / max. 80% relative humidity (non-condensing) |
Stray Light |
KI-solution at 220 nm < 3.3 Abs/ < 0.05% |
User Interface Languages |
bg, cn, cz, da, en, es, fr, gr, hr, hu, it, jp, kr, nl, pl, pt, ro, ru, sl, sl, sv, tr |
User Programs |
200 |
Warranty |
1 YEAR |
Wavelength Accuracy |
± 1 nm |
Wavelength Range |
190 - 1100 nm |
Wavelength Reproducibility |
< 0.1 nm |
Wavelength Resolution |
0.1 nm |
Wavelength Selection |
Automatic, based on method selection |
Weight |
11 kg |
PT.Mora Anugerah Berkat adalah perusahaan supplier alat portable spectrophotometer dan general laboratory yang sudah berpengalaman menjual/mensupply portable spectrophotometer ke seluruh indonesia, kami menyediakan berbagai brand/merek dunia serta menyediakan accesoris dari portable spectrophotometer,kami juga menyediakan Jasa Perawatan (Maintenance),Jasa Perbaikan (Sevice) dan membantu Kalibrasi (Calibration) jangan ragu untuk informasi,pertanyaan dan pemesanan silahkan hubungi kami.
Untuk mengetahui berbagai produk / bertanya informasi produk / ingin memesan produk, silahkan hubungi marketing kami siap membantu kebutuhan anda
PT.Mora Anugerah Berkat (M.A.B)
JL.Asri Blok M No 36 Kel.Cipadu Kec.Larangan Kota Tangerang, Provinsi Banten 15155
Phone : (+62)021 - 7366.0160/7345.7064
Fax : (+62)021 7366.0160
Mobile : 0812.8140.0749 / 0812.8770.5470
Chat : Whats App,Line,WeChat,Telegram
Website : www.moraanugerah.id # www.moraanugerah.com
Email : info@moraanugerah.id # info@moraanugerah.com