Blog


METTLER TOLEDO - XP504 Specification

PT. Mora Anugerah Berkat adalah perusahaan yang sudah berpengalaman dalam menyediakan / mensupply peralatan laboratorium pengukuran khususnya Micro Balance, Semi Miro-Balance, Analytical Balance, Precision Balance, Industrial Balance, Platform Scale dan masih banyak lagi. Salah satu diantaranya adalah Produk METTLER TOLEDO Series ( Shipping Scales/Platform Scale, Moisture Analyzers, Jewelry Scales, Ultra & Micro Laboratory Scales, Analytical Laboratory Scales,Laboratory Scales, Precision Laboratory Scales, Excellence Level,Mass Comparator ) kami juga menyediakan peralatan yang terbaik,sudah teruji dan sesuai dengan standard ASTM/JIS dll,kami juga menyediakan berbagai brand/merk internasional dari USA,Eropa dan China.


METTLER TOLEDO - XP504 Specification


SmartGrid™ Weighing Pan


SmartSens™ Sensors

  • For hands-free operation and personnel security
  • Enable user to tare, open and close draft shield or print without touching the balance
  • Promote safe handling of samples, prevention of spills, minimized contamination risk

Standard Features

  • Prepared for weighing below the balance
  • User administration and password protection
  • Target weighing
  • Statistical evaluation
  • Formulation with security check
  • Density determination
  • Percent weighing
  • Piece counting with reference optimization
  • Alphanumeric data entry of four IDs


METTLER TOLEDO - XP504 Specification


XP Analytical Balances
Technical Data (Limit Values)XP105DRXP205XP205DR
Maximum Capacity120 g220 g220 g
Maximum Capacity, Fine Range31 g--81 g
Readability0.1 mg0.01 mg0.1 mg
Readability, Fine Range0.01 mg--0.01 mg

Repeatability

– (at nominal load)0.06 mg (100 g)0.03 mg (200 g)0.06 mg (200 g)
– (at low load)0.05 mg (10 g)0.015 mg (10 g)0.05 mg (10 g)
– (at low load),
fine range
0.015 mg (10 g)--0.015 mg (10 g)
Linearity0.15 mg0.1 mg0.15 mg
Excentric Load Deviation (test load) 1)0.2 mg (50 g)0.2 mg (100 g)0.25 mg (100 g)
Sensitivity Offset4x10-6 Rnt2x10-6 Rnt2.5x10-6 Rnt
Sensitivity Temperature Drift 2)1x10-6/°C Rnt1x10-6/°C Rnt1x10-6/°C Rnt
Sensitivity Stability 3)1x10-6/a Rnt1x10-6/a Rnt1x10-6/a Rnt
Interface Update Rate23/s23/s23/s
Click Here : METTLER TOLEDO [XP Analytical Balance & XP Mricrobalance] Brochure
XP Analytical Balances
Technical Data (Limit Values)XP204XP504XP504DR
Maximum Capacity220 g520 g520 g
Maximum Capacity, Fine Range----101 g
Readability0.1 mg0.1 mg1 mg
Readability, Fine Range----0.1 mg

Repeatability

– (at nominal load)0.07 mg (200 g)0.12 mg (500 g)0.6 mg (500 g)
– (at low load)0.05 mg (10 g)0.1 mg (10 g)0.5 mg (10 g)
– (at low load),
fine range
----0.1 mg (10 g)
Linearity0.2 mg0.4 mg0.5 mg
Excentric Load Deviation (test load) 1)0.25 mg (100 g)0.4 mg (200 g)0.5 mg (200 g)
Sensitivity Offset3x10-6 Rnt3x10-6 Rnt4x10-6 Rnt
Sensitivity Temperature Drift 2)1x10-6/°C Rnt1x10-6/°C Rnt1x10-6/°C Rnt
Sensitivity Stability 3)1x10-6/a Rnt1x10-6/a Rnt1x10-6/a Rnt
Interface Update Rate23/s23/s23/s


INCLUDES :

Automatic and detachable draft shield, automatic inner draft shield, ProFACT automatic calibration technology, RS-232-C interface, option slot for second interface (choice of seven different interfaces), protective cover, detachable and adjustable terminal.


METTLER TOLEDO - XP504 Specification


Kami juga menyediakan Jasa Perbaikan (SERVICE), Jasa Perawatan (Maintenace) dan support untuk KALIBRASI / AKSESSORIES SPAREPART jangan ragu untuk menghubungi kami marketing dan sales kami siap membantu menjawab segala kebutuhan anda