CX33 Microscope
For less demanding requirements using only brightfield and darkfield, the CX33 microscope is a great option. The low- positioned nosepiece and stage, focusing lock, specimen holder, and inward quadruple revolving nosepiece make the CX33 microscope is well-suited for everyday observations in one easy configuration.
Click Here : Olympus Microscope Brochure
CX43 Specifications | |
Optical System | Infinity optical system |
Illumination System | · Built-in transmited illumination system · Köhler illumination (fixed field diaphragm) · LED power consumption 2.4 W (nominal value), precentered |
Focusing | · Stage height movement (coarse movement stroke: 15 mm ) · Stroke per rotation for coarse adjustment knob: 36.8 mm, Focusing stopper · Torque adjustment for coarse adjustment knob · Fine focus knob (minimum adjutsment gradations: 2.5 μm) |
Revolving Nosepiece | Fixed quadruple nosepiece with inward tilt |
Stage | · Wire movement mechanical fixed stage, (W × D): 211 mm × 154 mm · Traveling range (X × Y): 76 mm × 52 mm · Single specimen holder (optional: double specimen holder, sheet holder ) · Specimen position scale · Stage XY movement stopper |
Observation Tube | · 30° inclined trinocular tube (anti-fungal) · Light path selector: eyepiece/camera port = 100/0 or 0/100 · Interpupillary distance adjusting range: 48‒75 mm · Eyepoint adjustment: 375.0‒427.9 mm |
Eyepieces (anti-fungal) | · 10X Field Number (FN): 20 · 15X Field Number (FN): 16 (optional) |
Condenser | · Abbe condenser NA 1.25 with oil immersion · Built-in aperture iris diaphragm |
Observation Methods | Brightfield, darkfield |
Objectives | Plan achromat, anti-fungal 4X NA 0.1 W.D. 27.8 mm 10X NA 0.25 W.D. 8.0 mm 20X NA 0.4 W.D. 2.5 mm (optional) 40X NA 0.65 W.D. 0.6 mm 100X NA 1.25 W.D. 0.13 mm (optional) |
Rated Voltage / Electric Current |
AC 100 - 240 V ; 50/60 Hz ; 0.4 A |
=======================================================
=======================================================
OLYMPUS Microscope CX Series
Click Here : Olympus Microscope Brochure
CX33 Specifications | |
Optical System | Infinity optical system |
Illumination System | · Built-in transmited illumination system · Köhler illumination (fixed field diaphragm) · LED power consumption 2.4 W (nominal value), precentered |
Focusing | · Stage height movement (coarse movement stroke: 15 mm ) · Stroke per rotation for coarse adjustment knob: 36.8 mm, Focusing stopper · Torque adjustment for coarse adjustment knob · Fine focus knob (minimum adjutsment gradations: 2.5 μm) |
Revolving Nosepiece | Fixed quadruple nosepiece with inward tilt |
Stage | · Wire movement mechanical fixed stage, (W × D): 211 mm × 154 mm · Traveling range (X × Y): 76 mm × 52 mm · Single specimen holder (optional: double specimen holder, sheet holder ) · Specimen position scale · Stage XY movement stopper |
Observation Tube |
· 30° inclined trinocular tube (anti-fungal) · Light path selector: eyepiece/camera port = 100/0 or 0/100 · Interpupillary distance adjusting range: 48‒75 mm · Eyepoint adjustment: 375.0‒427.9 mm |
Eyepieces (anti-fungal) |
· 10X Field Number (FN): 20 · 15X Field Number (FN): 16 (optional) |
Condenser | · Abbe condenser NA 1.25 with oil immersion · Built-in aperture iris diaphragm |
Observation Methods | Brightfield, darkfield |
Objectives | Plan achromat, anti-fungal 4X NA 0.1 W.D. 27.8 mm 10X NA 0.25 W.D. 8.0 mm 20X NA 0.4 W.D. 2.5 mm (optional) 40X NA 0.65 W.D. 0.6 mm 100X NA 1.25 W.D. 0.13 mm (optional) |
Rated Voltage / Electric Current |
AC 100 ‒240 V 50/60 Hz 0.4 A |
OLYMPUS Microscope CX Series
Untuk informasi,pertanyaan dan pemesanan silahkan hubungi kami di :