Blog


Mercury Analyzer RA-5A NIPPON

20 November 2024 ENVIROMENTAL TESTING BLOG

PT.Mora Anugerah Berkat (M.A.B) merupakan distributor/supplier dari alat-alat laboratorium khususnya dibidang laboratorium lingkungan, kami menyediakan alat pengujian lingkungan diantaranya adalah NIC - Mercury Analyzer RA-5A

The RA-5A delivers ultra-high sensitivity and excellent precision while only requiring 5ml os sample. The RA-5A is also environmentally-friendly thorughits direct purge design that reduces reagent consumption and waste production by over 80% versus comparable model without any need for compressed gases RA-5A has achieved the highest level sensivity and accuracy with new innovatory-crafted detector optics.

Mercury Analyzer RA-5A NIPPON

SampleNAverageC.V
0.05μg/L50.052μg/L2.2 %
0.10µg/L50.101μg/L1.70%

Click Here : Mercury Analyzer RA-5A NIPPON

Nippon Instruments Corporation
SpecificationsMercury Analyzer RA – 5A

Data

Processing

Software

Measurement PrincipleNon-dispersive double beam cold vaporatomatic absorption spectrometry [Patent Pending]
Measurement MethodReducing Vaporrization with open air-supply (Peak height measuring and integration measuring salectable)
Light SourceLow pressure mercury discharge lamp
Wave Length253.7 nm
Detectorsemicondutor sensor (w/254nm bandpass filter)
Detection Limit0,0025ng/5ml (0.5ppt)
Maximum Range2.000ng/5ml (400 ppb)
Carrier Gas RequiredNo0 Compressed purified gas Required
Measure Flow RateAdjustable (0.1 - 0.9 L/min) (just operet with ambient air)
Measuring Time30sec - 999sec
DehumidifierPeltier device
Mercury RemovalRemoval by activated carbon

Mercury

Detection

Section

OSWindows 10 Pro
ComunicationUSB
DisplayPeak Wave shape,calibration curve,measuring time and measuring result
DataSelectable from 6 formula (3 liniear and 3rd order fits), Correlation
Processingcoefficient is automatically calculated Static calculation : Mean Value,standard deviation Coefficient of variation
Software(All value are automatically calculated), self check function
PrintMeasuring conditions,Calibration Curve,Measured values,Statical Calculations Peak wave shape and Measuring time
Quality ControlCheck Standard, Avoid abnormally high mercury
Instalation Dimension248W x 253D x 180H (mm)
Weight4,7 (Kg)
Instalation Enviroment10°C - 35°C, < 10 - 80% RH (Non condensing enviroment is allowed)
Power SupplyAC, single phase, 100 - 240V 50/60 Hz, 150VA (AC Adaptor Included)

Mercury Analyzer RA-5A NIPPON

Kami juga menyediakan Jasa Perbaikan (SERVICE), Jasa Perawatan (Maintenace) dan support untuk KALIBRASI / AKSESSORIES SPAREPART jangan ragu untuk menghubungi kami marketing dan sales kami siap membantu menjawab segala kebutuhan anda.

  • PT. Mora Anugerah Berkat (M.A.B)
  • Click Here : NIC Mercury Analyzer RA-5A Brochure
  • Alamat : Jl.Taman Asri Blok M No.36 Kel.Cipadu Kec.Larangan,Kota Tangerang - Provinsi Banten
  • Phone : 021 7345.7064
  • Mobile : 0812.8140.0749 / 0812.8770.5470
  • Chat: Whats App,Line,WeChat,Telegram
  • Website : www.moraanugerah.id - www.moraanugerah.com
  • Email : info@moraanugerah.com - marketing@moraanugerah.com - marketing_div@moraanugerah.com