Mercury Analyzer RA-5A NIPPON
PT.Mora Anugerah Berkat (M.A.B) merupakan distributor/supplier dari alat-alat laboratorium khususnya dibidang laboratorium lingkungan, kami menyediakan alat pengujian lingkungan diantaranya adalah NIC - Mercury Analyzer RA-5A
The RA-5A delivers ultra-high sensitivity and excellent precision while only requiring 5ml os sample. The RA-5A is also environmentally-friendly thorughits direct purge design that reduces reagent consumption and waste production by over 80% versus comparable model without any need for compressed gases RA-5A has achieved the highest level sensivity and accuracy with new innovatory-crafted detector optics.
Mercury Analyzer RA-5A NIPPON
Sample | N | Average | C.V |
0.05μg/L | 5 | 0.052μg/L | 2.2 % |
0.10µg/L | 5 | 0.101μg/L | 1.70% |
Click Here : Mercury Analyzer RA-5A NIPPON
Nippon Instruments Corporation | ||
Specifications | Mercury Analyzer RA – 5A | |
Data | Measurement Principle | Non-dispersive double beam cold vaporatomatic absorption spectrometry [Patent Pending] |
Measurement Method | Reducing Vaporrization with open air-supply (Peak height measuring and integration measuring salectable) | |
Light Source | Low pressure mercury discharge lamp | |
Wave Length | 253.7 nm | |
Detector | semicondutor sensor (w/254nm bandpass filter) | |
Detection Limit | 0,0025ng/5ml (0.5ppt) | |
Maximum Range | 2.000ng/5ml (400 ppb) | |
Carrier Gas Required | No0 Compressed purified gas Required | |
Measure Flow Rate | Adjustable (0.1 - 0.9 L/min) (just operet with ambient air) | |
Measuring Time | 30sec - 999sec | |
Dehumidifier | Peltier device | |
Mercury Removal | Removal by activated carbon | |
Mercury | OS | Windows 10 Pro |
Comunication | USB | |
Display | Peak Wave shape,calibration curve,measuring time and measuring result | |
Data | Selectable from 6 formula (3 liniear and 3rd order fits), Correlation | |
Processing | coefficient is automatically calculated Static calculation : Mean Value,standard deviation Coefficient of variation | |
Software | (All value are automatically calculated), self check function | |
Measuring conditions,Calibration Curve,Measured values,Statical Calculations Peak wave shape and Measuring time | ||
Quality Control | Check Standard, Avoid abnormally high mercury | |
Instalation Dimension | 248W x 253D x 180H (mm) | |
Weight | 4,7 (Kg) | |
Instalation Enviroment | 10°C - 35°C, < 10 - 80% RH (Non condensing enviroment is allowed) | |
Power Supply | AC, single phase, 100 - 240V 50/60 Hz, 150VA (AC Adaptor Included) |
Mercury Analyzer RA-5A NIPPON
Kami juga menyediakan Jasa Perbaikan (SERVICE), Jasa Perawatan (Maintenace) dan support untuk KALIBRASI / AKSESSORIES SPAREPART jangan ragu untuk menghubungi kami marketing dan sales kami siap membantu menjawab segala kebutuhan anda.
- PT. Mora Anugerah Berkat (M.A.B)
- Click Here : NIC Mercury Analyzer RA-5A Brochure
- Alamat : Jl.Taman Asri Blok M No.36 Kel.Cipadu Kec.Larangan,Kota Tangerang - Provinsi Banten
- Phone : 021 7345.7064
- Mobile : 0812.8140.0749 / 0812.8770.5470
- Chat: Whats App,Line,WeChat,Telegram
- Website : www.moraanugerah.id - www.moraanugerah.com
- Email : info@moraanugerah.com - marketing@moraanugerah.com - marketing_div@moraanugerah.com