Blog


Timbangan Mettler Toledo XP504DR

PT. Mora Anugerah Berkat adalah perusahaan yang sudah berpengalaman dalam menyediakan / mensupply peralatan laboratorium pengukuran khususnya Micro Balance, Semi Miro-Balance, Analytical Balance, Precision Balance, Industrial Balance, Platform Scale dan masih banyak lagi. Salah satu diantaranya adalah Produk METTLER TOLEDO Series ( Shipping Scales/Platform Scale, Moisture Analyzers, Jewelry Scales, Ultra & Micro Laboratory Scales, Analytical Laboratory Scales,Laboratory Scales, Precision Laboratory Scales, Excellence Level,Mass Comparator ) kami juga menyediakan peralatan yang terbaik,sudah teruji dan sesuai dengan standard ASTM/JIS dll,kami juga menyediakan berbagai brand/merk internasional dari USA,Eropa dan China.


Timbangan Mettler Toledo XP504DR


SmartGrid™ Weighing Pan


SmartSens™ Sensors

  • For hands-free operation and personnel security
  • Enable user to tare, open and close draft shield or print without touching the balance
  • Promote safe handling of samples, prevention of spills, minimized contamination risk

Standard Features

  • Prepared for weighing below the balance
  • User administration and password protection
  • Target weighing
  • Statistical evaluation
  • Formulation with security check
  • Density determination
  • Percent weighing
  • Piece counting with reference optimization
  • Alphanumeric data entry of four IDs


Timbangan Mettler Toledo XP504DR


XP Analytical Balances
Technical Data (Limit Values)XP105DRXP205XP205DR
Maximum Capacity120 g220 g220 g
Maximum Capacity, Fine Range31 g--81 g
Readability0.1 mg0.01 mg0.1 mg
Readability, Fine Range0.01 mg--0.01 mg

Repeatability

– (at nominal load)0.06 mg (100 g)0.03 mg (200 g)0.06 mg (200 g)
– (at low load)0.05 mg (10 g)0.015 mg (10 g)0.05 mg (10 g)
– (at low load),
fine range
0.015 mg (10 g)--0.015 mg (10 g)
Linearity0.15 mg0.1 mg0.15 mg
Excentric Load Deviation (test load) 1)0.2 mg (50 g)0.2 mg (100 g)0.25 mg (100 g)
Sensitivity Offset4x10-6 Rnt2x10-6 Rnt2.5x10-6 Rnt
Sensitivity Temperature Drift 2)1x10-6/°C Rnt1x10-6/°C Rnt1x10-6/°C Rnt
Sensitivity Stability 3)1x10-6/a Rnt1x10-6/a Rnt1x10-6/a Rnt
Interface Update Rate23/s23/s23/s
Click Here : METTLER TOLEDO [XP Analytical Balance & XP Mricrobalance] Brochure
XP Analytical Balances
Technical Data (Limit Values)XP204XP504XP504DR
Maximum Capacity220 g520 g520 g
Maximum Capacity, Fine Range----101 g
Readability0.1 mg0.1 mg1 mg
Readability, Fine Range----0.1 mg

Repeatability

– (at nominal load)0.07 mg (200 g)0.12 mg (500 g)0.6 mg (500 g)
– (at low load)0.05 mg (10 g)0.1 mg (10 g)0.5 mg (10 g)
– (at low load),
fine range
----0.1 mg (10 g)
Linearity0.2 mg0.4 mg0.5 mg
Excentric Load Deviation (test load) 1)0.25 mg (100 g)0.4 mg (200 g)0.5 mg (200 g)
Sensitivity Offset3x10-6 Rnt3x10-6 Rnt4x10-6 Rnt
Sensitivity Temperature Drift 2)1x10-6/°C Rnt1x10-6/°C Rnt1x10-6/°C Rnt
Sensitivity Stability 3)1x10-6/a Rnt1x10-6/a Rnt1x10-6/a Rnt
Interface Update Rate23/s23/s23/s


INCLUDES :

Automatic and detachable draft shield, automatic inner draft shield, ProFACT automatic calibration technology, RS-232-C interface, option slot for second interface (choice of seven different interfaces), protective cover, detachable and adjustable terminal.


Timbangan Mettler Toledo XP504DR


Kami juga menyediakan Jasa Perbaikan (SERVICE), Jasa Perawatan (Maintenace) dan support untuk KALIBRASI / AKSESSORIES SPAREPART jangan ragu untuk menghubungi kami marketing dan sales kami siap membantu menjawab segala kebutuhan anda