Radiant Heat Warmer
Introduction :
Infant Radiant Warmer is one of the important equipment used in medical institutions. It is mainly used for constant temperature cultivation, temperature resuscitation, oxygen delivery, rescue, hospitalization and observation of sick infants and premature infants. It is used in hospitals, confinement centers, neonatology, etc.
Features :
- LCD display
- Double control modes of bed temperature and skin temperature
- Double-layer thermostatic cover, automatic air curtain device
- Humidity control function
- Air & Oxygen blender
- Oxygen supply system
- Baby cot is infinitely adjustable
- 24 kinds of sound and light alarm, comprehensive protection of baby safety
Radiant Heat Warmer
CLICK HERE : INFANT RADIANT WARMER CATALOGUE
Technical Parameters :
Item | Specifications | |
General Parameters | Power Supply | AC220V,50/60Hz(Standard) 1320VA; 110V 60Hz (Optional) |
Size (L*W*H) | 950*645*(1250-11450) mm | |
Maximum heater output power (220VAC) | Air chamber heater: 330W; | |
Water tank heater: 155W | ||
Auxillary network power output | AC220V/50Hz, Both maximum permissible currents are 220V 1.5A | |
Heater indication | 0-100%, 10% increasing amount | |
Temperature control mode | Bed temperature mode; The skin temperature mode | |
Bed temperature control | 25.0 - 37.0°C; | |
temperature range | 37.1 - 39.0°C (Span Mode) | |
Skin temperature sensor temperature display range | 5.0 - 65.0°C | |
Heating time | < 50min | |
Temperature variability | < 0.5°C | |
Temperature uniformity (mattress in horizontal position) | < 0.8°C | |
Temperature uniformity (mattress in tilted position) | < 1.0°C | |
Difference between average incubator temperature and control temperature | < 1.5°C | |
Skin temperature sensor accuracy | +0.3°C |
Humidity Control | The running time of the tank after it is filled with distilled water | Humidity below 70%RH, at least 24h |
Water tank capacity | 1500ml | |
Humidity display range | 0%RH - 99%RH | |
Humidity control range | CAH%RH - 90%RH(1% per adjustment) | |
Humidity control accuracy | +100% | |
Oxygen Concentration Control | Oxygen concentration display range | 0% - 99% |
Oxygen concentration display resolution | 1% | |
Oxygen concentration control accuracy | +5% oxygen volume concentration | |
Oxygen concentration setting range | 21% - 60% (1% per adjustment) | |
Oxygen sensor service life | The maximum use time is 10000h at 100% oxygen concentration | |
Transport Storage | Temperature | -2°C - +55°C |
Atmospheric pressure range | 500hPa - 1060hPa | |
Relative humidity | < 93% RH | |
Packing size/Gross Weight | Base packing size: 1200*800*870mm 50kg | |
Body packing size: 1100*710*855mm 60kg | ||
The Work Environmenr | Relative humidity | 30%RH - 75%RH |
The environment temperature | +20°C - + 30°C | |
Pressure range | 700hPa - 1060hPa | |
Service altitude | < 2000m | |
Over voltage category | II | |
Pollution levels | 2 | |
Ambient air velocity | < 0.3m/s | |
Environmental noise in incubator baby compartment | No more than 55dB(A) at stable temperature | |
Carbon dioxide concentration in the infant compartment | A mixture of 4% carbon dioxide and air was fed into an 8mm diameter tube in the vertical direction from the mat to the top of the box at 750mL/min to a point 10cm above the mattress center and 10cm above the center. The concentration was less than 0.5% after stabilization | |
The velocity of air flow over a baby's mattress | < 0.35m/s | |
General Alarm | Power off alarm, Fan alarm, sensor alarm, Deviation alarm, Over temperature alarm, Water tank placement error alarm, Water shortage alarm | |
The System Alarm | Mcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, Analog-to-digital conversion chip 2544 fault alarm, Analog-to-digital conversion chip 2548 fault alarm, Over temperature alarm, Temperature heating system fault, Humidity heating system fault |
Configuration :
Model | BK-3201 (I) | BK-3201 (II) |
Temp.Control | Bed/Skin temperature | Bed/Skin temperature |
Display | LCD | LCD |
Bed Temp. Control Range | 25°C - 39°C | 25°C - 39°C |
Skin Temp. Control Range | 34°C - 38°C | / |
Humidity Control Range | CAH% - 99%RH | CAH% - 99%RH |
Oxygen Control Range | 21% - 99% | / |
Cabinet | Yes | Yes |
PT.Mora Anugerah Berkat adalah perusahaan yang sudah berpengalaman dalam menyediakan/mensupply peralatan laboratorium untuk Medical & Hospital seperti Infant Radiant Warmer, kami juga menyediakan peralatan baik lokal maupun custom (khusus) yang sudah teruji dan sesuai dengan ASTM,kami juga menyediakan berbagai brand/merk internasional dari USA,Eropa dan China,etc.
Kami juga menyediakan Jasa Perbaikan (SERVICE),Jasa Perawatan (Maintenace) dan support untuk KALIBRASI/AKSESSORIES SPAREPART jangan ragu untuk menghubungi kami marketing dan sales kami siap membantu menjawab segala kebutuhan anda.
Radiant Heat Warmer
CLICK HERE : INFANT RADIANT WARMER CATALOGUE
- Click Here : MEDICAL HOSPITAL CATALOGUE
- PT. Mora Anugerah Berkat (M.A.B)
- Jl.Taman Asri Blok M No.36 Kel.Cipadu Kec.Larangan,Kota Tangerang - Provinsi Banten
- Phone : (+62) 21 7345.7064 / 7366.0160
- Mobile: 0812.8140.0749 / 0812.8770.5470 (Chat : Whats App,Line,WeChat,Telegram)
- Website : http://moraanugerah.id/ - http://moraanugerah.com/
- Email : info@moraanugerah.com - info@moraanugerah.id -marketing_div@moraanugerah.comJual Marsh Funnel Viscometer