HACH 2100Q PORTABLE TURBIDIMETER
The Hach 2100Q Portable Turbidimeter offers unsurpassed ease of use and accuracy in turbidity measurement. Only Hach offers this unique combination of advanced features and measurement innovation, giving you accurate results every time. The USB+Power Module provides additional benefit by allowing the user to transfer data to a PC in XML format, transfer data to the Citizen PD-24 printer (2960100), operate the instrument on line power (100-240Vac, 50/60 HZ), charge NiMH batteries (2971304),perform firmware updates, and quickly enter Sample and User IDs with the optional barcode scanner (LZV566).
SPESIFICATIONS
Accuracy |
± 2 % of reading plus stray light |
Battery Requirements | 4, AA |
Certifications | CE certified |
Compliance Certifications |
CE/WEEE |
Data Logging | 500 records |
Dimensions (H x W x D) |
77 mm x 107 mm x 229 mm |
Display Size |
240 x 160 pixels |
Display Type | Graphic LCD |
Enclosure Rating |
IP67 |
Height | 3.0 in |
Includes | Instrument, case assembly, 4 AA alkaline batteries, 6 sample cells, StablCal ampule kit, silicone oil, oiling cloth, manual. |
Interface | USB |
Light Source |
tungsten filament lamp |
Manual Languages | English, French, German, Italian, Spanish, Portuguese (BR), Portuguese (PT), Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish |
Max. Operating Humidity |
90 % |
Measurement Method | Ratio turbidimetric determination using a primary nephelometric light scatter signal (90°) and transmitted light scatter signal. |
Measurement Modes | Normal (Push to Read), Signal Averaging, Rapidly Settling Turbidity |
Operating Temperature Range |
0 - 50 °C |
Power Requirements | 100 - 240 VAC, 50/60 Hz (with included USB+Power module) |
Power Supply | Batteries (see Battery Requirements) |
Range |
0 - 1000 |
Range 2 |
NTU |
Reading Modes | Normal (Push to Read) ; Signal Averaging Rapidly Setting Turbidity |
Regulatory | EPA Method 180.1 |
Repeatability |
± 1 % of reading or 0.01 NTU , whichever is greater |
Response Time |
6 sec in normal reading mode |
Sample Cell Compatibility |
25 mm x 60 mm round |
Sample Requirements |
15 mL (0.5 oz.) |
Sample Volume |
15 mL (0.5 oz.) |
Signal Averaging |
Selectable on/off |
Storage Conditions |
-40 °C to 60 °C |
Stray Light |
< 0.02 NTU |
Units | NTU |
User Interface | Button Graphic User Interface |
User Interface Languages | English, French, German, Italian, Spanish, Portuguese (BR), Portuguese (PT), Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish |
Warranty |
1 year |
TL2300 LABORATORY TURBIDIMETERS
The new TL23 Series laboratory turbidimeters blend trusted technology and improved features to simplify testing in the most demanding industrial and wastewater applications.
Hach's new TL23 lab turbidimeter brings a new face to the trusted legacy 2100N and 2100AN turbidimeters. It utilizes the same optic bloc while delivering an improved user experience with its intuitive interface, which ties perfectly to the rest of Hach's laboratory instruments.
Having the same optic bloc means that you can replace your old 2100N/AN with a TL23 turbidity meter without having tochange any of your standard operating procedures.
SPECIFICATIONS
Accuracy |
Ratio on: ±2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of reading from 1000 - 4000 NTU based on formazin primary standard Ratio off: ±2% of reading plus 0.01 NTU from 0 - 40 NTU |
Air Purge | Dry nitrogen or instrument grade air (ANSI MC 11.1, 1975) 0.1 scfm at 69 kPa (10 psig); 138 kPa (20 psig) max Hose barb connection for 1/8-inch tubing |
Certifications | CE, KC, RCM |
Communication | USB |
Data Logging | 2000 total logs, includes reading log, verification log and calibration log |
Dimensions (H x W x D) |
153 mm x 395 mm x 305 mm |
Display | 17.8 mm (7 in.) color touch screen |
Interface |
2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner |
Light Source | Tungsten filament lamp |
Measurement Method | Nephelometric |
Model | TL2300 EPA |
Operating Temperature Range |
0 - 40 °C |
Power Requirements (Amps) |
3.4 A |
Power Requirements (Hz) |
50/60 Hz |
Power Requirements (Voltage) |
100 - 240 VAC |
Range |
NTU (Ratio on): 0 - 4000 ; NTU (Ratio off): 0 - 40 EBC (Ratio on): 0 - 980 ; EBC (Ratio off): 0 - 9.8 |
Reading Modes | Single, continuous, Rapidly Settling Turbidity™, signal averaging on or off, ratio on or off |
Regulatory |
Meets EPA Method 180.1 |
Repeatability |
±1% of reading or 0.01 NTU, whichever is greater (under reference conditions) |
Response Time | Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average) |
Sample Cell Compatibility |
Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps Note: Smaller sample cells(less than 25 mm) can be used when a cell adapter is used. |
Sample Requirements | 25 mm sample cell: 20 mL minimum 0 to 70 °C (32 to 158 °F) |
Stabilization Time | Ratio on: 30 minutes after start-up Ratio off: 60 minutes after start-up |
Storage Conditions | -20 to 60 °C |
Units | NTU and EBC |
Weight |
3.0 kg |
TU5200 LABORATORY TURBIDIMETER
The TU5200 laboratory turbidimeter is part of Hach's TU5 series online and laboratory turbidimeters, designed specifically for the drinking water and other ultra pure water applications with an identical optic bloc in both the online and laboratory instruments.
Only the new TU5 Series Lab & Process Turbidimeters with 360° x 90° Detection deliver unprecedented confidence that a change in your reading is a change in your water.
SPESIFICATIONS
Accuracy | ±2 % plus 0.01 NTU from 0 - 40 NTU; ±10 % of reading from 40 - 1000 NTU based on Formazin primary standard (at 25 °C) |
Calibration Method | For Formazin and Stablcal: 20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range Custom calibration for up to 6-point calibrations Degrees 0 - 100 mg/L ; SDVB 0 - 1000 NTU |
Certifications |
CE compliant US FDA accession number: 1420493-000 EPA version, 1420492-000ISO version Complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50) ; Australian ACMA Marking |
Communication | Link2sc and RFID |
Dimensions (H x W x D) |
195 mm x 409 mm x 278 mm |
Display |
7" WVGA (800 x 480) color TFT-LCD with touch screen |
Enclosure Construction |
PC/ABS Blend Plastic |
Light Source | Class 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50) |
Model |
TU5200 EPA |
Operating Humidity |
80 % at 30 °C (non condensing) |
Operating Temperature Range |
10 - 40 °C |
Power Requirements (Hz) |
50/60 Hz |
Power Requirements (Voltage) |
100 - 240 VAC |
Range |
EPA: 0 - 700 NTU / FNU / TE/F / FTU 0 - 100 mg/L ; 0 - 175 EBC ISO: 0 - 1000 NTU / FNU / TE/F / FTU 0 - 100 mg/L ; 0 - 250 EBC |
Regulatory | EPA |
Repeatability | <40 NTU: Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater >40 NTU: Better than 3.5% of reading on Formazin at 25 °C (77 °F) |
Resolution | 0.0001 NTU / FNU / TE/F / FTU / EBC / mg/L |
Response Time |
Signal averaging off: 7 seconds Signal averaging on: 10 seconds (when averaging time is 5 seconds) |
Sample Temperature | 4 - 70°C (39 - 158°F) |
Storage Conditions |
-30 to 60 °C (-22 to 140 °F) |
Stray Light | <10 mNTU |
Units |
NTU, FNU, TE/F, FTU, EBC; mg/L if calibrated with Degrees calibration curve |
Warranty | 1 YEAR |
Weight | 2.4 kg |
Untuk mengetahui berbagai produk / bertanya informasi produk / ingin memesan produk, silahkan hubungi marketing kami siap membantu kebutuhan anda
PT.Mora Anugerah Berkat (M.A.B)
JL.Asri Blok M No 36 Kel.Cipadu Kec.Larangan Kota Tangerang, Provinsi Banten 15155
Phone : (+62)021 - 7366.0160/7345.7064
Fax : (+62)021 7366.0160
Mobile : 0812.8140.0749 / 0812.8770.5470
Chat : Whats App,Line,WeChat,Telegram
Website : www.moraanugerah.id # www.moraanugerah.com
Email : info@moraanugerah.id # info@moraanugerah.com