IKA CALORIMETER C 6000 DAN C 7000
C 6000 (An Evolution in Calorimetry)
The champion of modern calorimetry has been developed even further. The new C 6000 has an intuitive touch screen with unique user guidance. The high level of automation simplifies everyday work and enables high sample throughput. The strictest adherence to standards gives rise to the most accurate repeatable results in the world and guarantees the desired assurance.
Especially suitable for: sectors in which adherence to standards is a prerequisite and a large number of samples need to be measured
C 6000 Functions
The new movement-sensitive touch screen
guarantees even easier, more intuitive use.
The C 6000 easily meets all standards.
> Easily-accessible USB interface for simple, enhanced data management
> Ethernet interface for data management via an FTP server
> Spherically-shaped decomposition vessel for improved heat transfer and shorter measurement times
> Powerful device software with a control chart view of calibration and calorific value corrections, compliant with globally-applicable standards
> RFID technology for decomposition vessel detection
> Inverted crucible holder for easier measurement preparation
> 3 starting temperatures: 22 °C, 25 °C, 30 °C
Your Laboratory, our C 6000 Package
The C 6000 is available in global standards or isoperibolic versions. Thanks to the innovative technology of the C 6000 global standards, conventional adiabatic as well as isoperibolic measurement methods can be used.
This makes it the only device withsuch a high level of automation in the market. Both variants also have a fast dynamic mode.
What do you need? Just get in contact with us!
C 6000 Global Standards Packages
C 6000 PACKAGE 1/10 | Ident. No. 0010004520
C 6000 Calorimeter, C 6010 Decomposition vessel ,RC 2 basic Circulating chiller
C 6000 PACKAGE 1/12 | Ident. No. 0010004521
C 6000 Calorimeter, C 6012 Decomposition vessel, halogen resistant, RC 2 basic Circulating chiller
C 6000 Package 2/10 | Ident. No. 0010004522
C 6000 Calorimeter, C 6010 Decomposition vessel
C 6000 Package 2/12 | Ident. No. 0010004523
C 6000 Calorimeter, C 6012 Decomposition vessel, halogen resistant
C 6000 Isoperibol Packages
C 6000 Package 1/10 | Ident. No. 0010004524
C 6000 Calorimeter, C 6010 Decomposition vessel,RC 2 basic Circulating chiller
C 6000 Package 1/12 | Ident. No. 0010004525
C 6000 Calorimeter, C 6012 Decomposition vessel, halogen resistant, RC 2 basic Circulating chiller
C 6000 Package 2/10 | Ident. No. 0010004526
C 6000 Calorimeter, 6010 Decomposition vessel
C 6000 Package 2/12 | Ident. No. 0010004527
C 6000 Calorimeter, C 6012 Decomposition vessel, halogen resistant
Technical Data | C 6000 Calorimeter |
---|---|
TECHNICAL DATA | |
Measuring range max | 40,000 J / 9,560 cal |
Temperature measurement resolution | 0.0001 K |
Oxygen operating pressure max. | 40 bar |
Measuring modes | > Isoperibol 22 / 25 / 30 °C > Dynamic 22 / 25 / 30 °C > Adiabatic 22 / 25 / 30 °C |
Reproducibility | |
(1g benzoic acid NBS39i) | 0.05 to 0.15 % RSD |
Measurements per hour | Isoperibol 4 Dynamic 6 Adiabatic 5 |
Number of possible decomposition vessels per device |
Up to 4 |
Decomposition vessels | C 6010 / C 6012 |
INTERFACES | |
PC | 9 pin (M) RS 232 serial |
Printer | USB-B, Ethernet |
Balance | 9 pin (M) RS 232 serial |
AUTOMATIC FUNCTIONS | |
Automatic water filling and draining |
Yes |
Automatic oxygen, venting, flushing | Yes |
Ignition and ignition energy determination for each experiment | Yes |
COOLING WITH RC 2 BASIC CHILLER | |
Cooling medium temperature min | 12 °C |
Cooling medium temperature max | 27 °C |
Cooling medium permissible operating pressure | 1.5 bar |
CALORIMETER STANDARDS | |
Analysis according to | GB T213 ; DIN EN ISO 1716 ; DIN CEN TS 14918 ; DIN EN 15170 ; ISO 1928 ; DIN 51900 ; ASTM D240 ; ASTM D4809 ; ASTM D5865 |
GENERAL DATA | |
Weight | 29 kg |
Dimensions (W × H × D) | 500 × 450 × 450 mm |
Permissible ambient temperature | 20 - 30 °C |
Permissible relative humidity | 80% |
Voltage | 220 - 240 V |
Frequency | 50 / 60 Hz |
Power input | 1,700 W |
Protection class according to DIN EN 60529 | IP 20 |
C 7000
The C 7000 is the first calorimeter from IKA to have a completely dry design. It measures the calorific values of liquid and solid samples directly in the decomposition system. Depending on the selected pre-testing time, the measurement times can be reduced to 3 to 7 minutes. The system can handle up to eight different decomposition vessels from one set of coding. This makes timely decisions and fast progress with work processes possible. It is especially popular in: the waste and disposal industry
C 7000 Functions
The dry device design enables extra-fast measurement in just a few minutes.
The especially robust design ensures a long service life, even under tough conditions.
> Precise, repeatable calorific value determination according to ISO 1928, DIN CEN/TS 16023, DIN EN 15400, DIN EN 15170,DIN EN ISO 18125
> Up to eight decomposition vessels per device can be used
Your Laboratory, our C 7000 Package
The C 7000 is available either as a variant with a standard decomposition vessel (Set 1) or with a halogen-resistant decomposition vessel (Set 2) for samples with a particularly high halogen
content, such as those, which especially occur in the waste industry.
What do you need? Just get in contact with us!
C 7000 SET 1 | Ident. No. 0008800900
C 7000 Measurement cell, C 7002 Cooling system,
C 48 Oxygen station, C 7010 Decomposition vessel
C 7000 SET 2 | Ident. No. 0008801400
C 7000 Measurement cell, C 7002 Cooling system,
C 48 Oxygen station, C 7012 Decomposition vessel,halogen resistant
Technical Data | C 7000 Calorimeter |
---|---|
Technical Data | |
Measuring range max. | 30,000 J |
Temperature measurement resolution | 0.0001 K |
Oxygen operating pressure max. | 40 bar |
Display | LED |
Measuring mode | Double Dry (ISO 1928) |
Double dry reproducibility (1g benzoic acid NBS39i) | 0.2 % RSD |
Working temperature max. | 30 °C |
Operation time double dry approx Number of Possible | 3 min |
decomposition vessels per device | 8 |
Decomposition vessels | C 7010 / C 7012 |
INTERFACES | |
PC | RS 232 Serial |
Printer | Centronix |
Balance | RS 232 Serial |
COOLING | |
Type Of Cooling | |
Cooling Medium | |
Cooling medium temperature min. Cooling medium temperature max |
12 °C 30 °C |
Cooling medium permissible operating pressure | 9 Bar |
GENERAL DATA | |
Weight | 43 kg |
Dimensions (W × H × D) | 310 × 395 × 490 mm |
Permissible ambient temperature | 18 - 30 °C |
Permissible relative humidity | 80% |
Voltage | 220 - 240 V |
Frequency | 50 / 60 Hz |
Power input | 260 W |