Brand : IKA,PARR Instrument
Stok : In Stock
IKA CALORIMETER (C1 AND C2 200 TYPE)
The C 1 is a tiny giant. It takes up hardly any space in the laboratory, yet offers a high degree of automation. Where there is no need for compliance with standards, however calorific values still need to be determined or processes tested with a high degree of accuracy, this calorimeter makes life so much easier.It works according to the isoperibolic principle and with a static jacket. This makes the C 1 a strong partner for industrial and testing laboratories.
It is especially popular in: the waste management industry, the foodstuffs and animal feed industry as well as in the construction materials sector.
C1 Functions
The light, easy-to-attach combustion chamber replaces the decomposition vessel with a screw cap.
The unit functions fully automatically, which makes it particularly user-friendly
> Automatic oxygen filling, venting and flushing
> Automatic ignition with a fixed ignition wire and ignition energy specification
> Automatic water filling and drainage
> Works with a chiller (RC 2 basic) or with an existing cold water connection and a heater (C 1.20, accessory)
> Interfaces for PC (USB-B), printer (serial interface), scales (serial interface)
Your Laboratory, our C 1 Package
What kind of laboratory do you have? With us, you will certainly find the right C 1 package. For example, if you only have a cold-water connection and your samples have a high halogen content, we recommend the C 1 package 3/12. The therein contained water heater guarantees the temperature required
for its operation and ensures reproducible results. The C 1.12 decomposition vessel, included in the delivery, provides the necessary corrosion protection for chlorinated samples.
What do you need? Just get in contact with us!
Packages including combustion chamber C 1.10
C 1 PACKAGE 1/10 | Ident. No. 0010002412
C 1 Calorimeter including RC 2 basic Circulating chiller
C 1 PACKAGE 2/10 | Ident. No. 0010002413
C 1 Calorimeter
C 1 PACKAGE 3/10 | Ident. No. 0010002414
C 1 Calorimeter including C 1.20 Heater
Packages including combustion chamber C 1.12
C 1 PACKAGE 1/12 | Ident. No. 0010002415
C 1 Calorimeter including RC 2 basic Circulating chiller,halogen resistant
C 1 PACKAGE 2/12 | Ident. No. 0010002416
C 1 Calorimeter, halogen resistant
C 1 PACKAGE 3/12 | Ident. No. 0010002417
C 1 Calorimeter including C 1.20 Heater,halogen resistant
Technical Data C 1 Calorimeter | |
---|---|
TECHNICAL DATA | |
Measuring range max | 40.000 J / 9,560 cal |
Temperature measurement resolution | 0.0001 K |
Oxygen operating pressure max. | 30 bar |
Display | TFT |
Multifunctional knob (turn / push) | Yes |
Reproducibility static jacket (1g benzoic acid NBS39i) | 0.15 % RSD |
Measurements per hour | 4 |
Jacket control | Static, dry |
Start temperature setting | 2 possibilities: 22 °C or 30 °C |
Number of possible decomposition vessels per device | Up to 2 |
INTERFACES | |
Interface PC | USB-B |
Interface Printer / Balance | 9 pin (M) RS 232 serial |
AUTOMATIC FUNCTIONS | |
Automatic oxygen filling, degasing and flushing | Yes |
Automatic water filling and draining | Yes |
"Automatic combustion with ignition wire and combustion | |
energy determination with every sample run" | Yes |
COOLING WITH RC 2 BASIC CHILLER | |
Cooling medium temperature min. | 18 °C |
Cooling medium temperature max | 29 °C |
Cooling medium permissible operating pressure | 1.5 bar |
Cooling medium | Tap water |
Type of cooling | Flow |
Flow rate min | 50 l/h |
Flow rate max | 60 l/h |
Recommended flow rate at 18 °C | 55 l/h |
GENERAL DATA | |
Languages |
DE, EN, FR, ES,
CN, RU, PO, IT |
Weight | 15 kg |
Dimensions open (W × H × D) | 290 × 400 × 300 mm |
Dimensions closed (W × H × D) | 290 × 280 × 300 mm |
Permissible ambient temperature | 20 - 25 °C |
Permissible relative humidity | 80% |
Voltage | 100 - 240 V |
Frequency | 50 / 60 Hz |
Power input | 150 W |
C 200 (The Perfect Entry-Level Calorimeter)
The C 200 works in compliance with several standards, saves space and is cost-effective. It consists of robust technology,making it especially low-maintenance. IKA also offers a “Student Mode” version of this combustion calorimeter, for schools, technical colleges, universities and national institutions. This is even clearer and more instructive, being used for educational purposes.
It is especially popular for: learning and educational purposes or laboratories with a small volume of samples
C 200 Functions
# Student Mode enables deep understanding of every stage of the calorimetric process.
# The C 200 is particularly space-saving.
> An easy-to-use display
> Four different testing methods: isoperibolic, manual, dynamic and time-controlled
isoperibolic | up to 17 min |
---|---|
dynamic | up to 8 min |
manual (isoperibol) | up to 17 min |
time-controlled | up to 14 min |
> Monitoring and visualization of the measurement process and management of measurement data using the C 6040 CalWin calorimeter software (accessory)
> GOST-certified
Your Laboratory, our C 200 Package
The C 200 auto and halogen-resistant C 200 h auto packages enable the C 200 to be operated with a completely automated water circuit. Water circulates in a closed circuit and is kept at aconstant temperature by the RC 2 basic circulation chiller. This reduces test preparation time for the user in the laboratory and leads to reproducible results.
What do you need? Just get in contact with us!
C 200 Packages
C 200 PACKAGE | Ident. No. 0008802500
C 200 Calorimeter, C 5010 Decomposition vessel,
C 248 Oxygen filling station
C 200 H PACKAGE | Ident. No. 0008803700
C 200 Calorimeter, C 200.2 Conversion kit for C 5012,
C 5012 Decomposition vessel, halogen resistant,
C 248 Oxygen filling station
C 200 Auto Packages
C 200 AUTO PACKAGE | Ident. No. 0010002379
C 200 Calorimeter, RC 2 basic Circulating chiller,
C 5010 Decomposition vessel, C 200.RC Set of hoses
C 200 H AUTO PACKAGE | Ident. No. 0010002387
C 200 h Calorimeter, RC 2 basic Circulating chiller,
C 5012 Decomposition vessel, halogen resistant,
C 200.RC Set of hoses
Technical Data C 200 Calorimeter | |
---|---|
TECHNICAL DATA | |
Measuring range max. | 40,000 J / 9,560 cal |
Temperature measurement resolution | 0.0001 K |
Measuring modes | > Isoperibol > Manual (Student mode) > Dynamic > Time controlled |
"Reproducibility | |
(1g benzoic acid NBS39i) " | 0.1 % RSD |
Operation time | > Isoperibol 17 min > Dynamic 8 min > Time controlled 14 min |
Working temperature max. | 25 °C |
"Number of possible | |
decomposition vessels per device" | Up to 4 |
Decomposition vessel | C 5010 / C 5012 |
INTERFACES | |
PC | RS 232 serial |
Printer | Centronix |
AUTOMATIC FUNCTIONS | |
Automatic water filling and draining | Yes |
Ignition | Yes (manual - No) |
COOLING WITH RC 2 BASIC CHILLER | |
Cooling medium | Tap water |
Type of cooling | Flow |
Cooling medium permissible operating pressure | 2 bar |
GENERAL DATA | |
Weight | 21 kg |
Dimensions (W × H × D) | 400 × 400 × 400 mm |
Permissible ambient temperature | 20 - 25 °C |
Permissible relative humidity | 80% |
Voltage | 100 - 240 V |
Frequency | 50 / 60 Hz |
Power input | 120 W |
Protection class according to DIN EN 60529 | IP 20 |
Click Here : IKA Oxygen Bomb Calorimeter Catalogue
Click Here : IKA Oxygen Bomb Calorimeter
Untuk mengetahui berbagai produk / bertanya informasi produk / ingin memesan produk, silahkan hubungi marketing kami siap membantu kebutuhan anda
PT.Mora Anugerah Berkat (M.A.B)
JL.Asri Blok M No 36 Kel.Cipadu Kec.Larangan Kota Tangerang, Provinsi Banten 15155
Phone : (+62)021 - 7366.0160/7345.7064
Fax : (+62)021 7366.0160
Mobile : 0812.8140.0749 # 0812.8770.5470
Chat : Whats App,Line,WeChat,Telegram
Website : www.moraanugerah.id # www.moraanugerah.com
Email : info@moraanugerah.id # info@moraanugerah.com