WATER PURIFICATION SYSTEM EQUIPMENT

Harga : Rp 0.00 Rp 1,000.00

Brand : Thermo Scientific™,Biolabs Scientific,Merck Millipore,Sartorius,Evoqua

Stok : In Stock





WATER PURIFICATION SYSTEM EQUIPMENT

BASIC WATER PURIFICATION SYSTEM 100 SERIES


This basic series is ideal for wide range of applications. It produces RO, Deionized water and Ultrapure water. The organic rejection rate is greater than 99% using reverse osmosis. The resistivity reaches up to 18.2MΩ.cm which completely meets the highest grade I standard.


SPESIFICATION

Model BBPS-101 BBPS-102 BBPS-103 BBPS-104
Feed Water Requirements*
Water Inlet Tap water: TDS < 200 ppm (Extra pretreatment filter is recommended,if TDS > 200ppm) Tap water: TDS < 200 ppm (Extra Pretreatment Filter is Recommended,if TDS > 200 ppm) Tap water: TDS < 200 ppm (Extra pretreatment filter is recommended,if TDS > 200ppm) Tap water: TDS< 200 ppm (Extra pretreatment filter is recommended,if TDS> 200 ppm)
Temperature 5-45°C 5-45°C 5-45°C 5-45°C
Pressure 1.0-4.0Kgf/cm² 1.0-4.0Kgf/cm² 1.0-4.0Kgf/cm² 1.0-4.0Kgf/cm²
Flow Procedure** PF+AC+RO+AC PF+AC+RO+AC PF+AC+RO+AC PF+AC+RO+AC
RO Water Quality
Ion Rejection Rate 96% - 99% (New RO membrane) 96% - 99% (New RO membrane) 96% - 99% (New RO membrane) 96% - 99% (New RO membrane)
Organic Rejection Rate > 99 % (when MW > 200 Dalton) > 99 % (when MW > 200 Dalton) > 99 % (when MW > 200 Dalton) > 99 % (when MW > 200 Dalton)
Particles and Bacteria Rejection Rate > 99% > 99% > 99% > 99%
Output(25°C)**** 15 L/hrs 30 L/hrs 45 L/hrs 15 L/hrs
Pure Water Outlet RO water RO water RO water RO water
Dimension LxWxH (mm) 410×320×420 410×320×420 410×320×420 410×400×420
Weight (Kg) 15 15 15 20
Main Body (Including 1 set of cartridges) + TDSpen + Accessory Bag Main Body (Including 1 set of cartridges) + TDSpen + accessory bag Main Body (Including 1 set of cartridges) + TDSpen + accessory bag Main Body (Including1 set of cartridges) + built-in10 liters tank + TDS pen+ accessory bag
Standard Configuration
Power Consumption (W) 72 72 120 72
Power Supply AC110 - 220V, 50/60 Hz AC110 - 220V, 50/60 Hz AC110 - 220V, 50/60 Hz AC110 - 220V, 50/60 Hz
Deionized Water Quality - - - -
Resistivity - - - -
Conductivity - - - -
Bacteria - - - -
Particle (> 0.2μm) - - - -


BBPS-105 BBPS-106 BBPS-107 BBPS-108
Tap Water : TDS < 200 ppm (Extra pretreatment filter is recommended, if TDS > 200ppm) Tap water: TDS < 200 ppm (Extra pretreatment filter is recommended, if TDS > 200ppm) Tap Water : TDS < 200 ppm (Extra pretreatment filter is recommended, if TDS > 200ppm) Tap Water : TDS < 200 ppm (Extra pretreatment filter is recommended, if TDS > 200ppm)
5-45°C 5-45°C 5-45°C 5-45°C
1.0-4.0Kgf/cm² 1.0-4.0Kgf/cm² 1.0-4.0Kgf/cm² 1.0-4.0Kgf/cm²
PF+AC+RO+AC PF+AC+RO+AC PF+AC+RO+DI PF+AC+RO+DI
96% - 99% (New RO membrane) 96% - 99% (New RO membrane) 96% - 99% (New RO membrane) 96% - 99% (New RO membrane)
> 99 % (when MW >200 Dalton) > 99 % (when MW>200 Dalton) > 99 % (when MW > 200 Dalton) > 99 % (when MW > 200 Dalton)
> 99 % > 99 % > 99 % > 99 %
30 L/hrs 45 L/hrs 15 L/hrs 30 L/hrs
RO water RO water RO and Deionized Water RO and Deionized Water
410 × 400 × 420 410 × 400 × 420 410 × 320 × 420 410 × 320 × 420
20 20 15 15
Main Body (Including 1 set of cartridges)+ built-in 10liters tank + TDS Pen+ accessory bag Main body (Including 1 set of cartridges)+ built-in 10liters tank + TDS pen+ accessory bag Main body (Including 1 set of cartridges) + TDS pen+ Accessory Bag Main body (Including 1 set of cartridges) +TDS pen+ accessory bag
72 120 72 72
AC110-220V, 50/60Hz AC110-220V, 50/60Hz AC110-220V, 50/60Hz AC110-220V, 50/60Hz
- - - >13-17.5MΩ.cm
- - - 0.057-0.077μs/cm
- - - <0.1cfu/ml (with terminal filter)
- - - Particle (>0.2μm)<1/ml (with terminalfilter)


BBPS-109 BBPS-110 BBPS-111
Tap Water : TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200ppm) Tap Water : TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200ppm) Tap Water : TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200ppm)
5-45°C 5-45°C 5-45°C
1.0-4.0Kgf/cm² 1.0-4.0Kgf/cm² 1.0-4.0Kgf/cm²
PF+AC+RO+DI PF+AC+RO+DI PF+AC+RO+DI
96%-99%(New RO membrane) 96%-99%(New RO membrane) 96%-99%(New RO membrane)
>99% (when MW>200 Dalton) >99% (when MW>200 Dalton) >99% (when MW>200 Dalton)
>99% >99% >99%
45 L/hrs 15 L/hrs 30 L/hrs
RO and Deionized Water RO and Deionized Water RO and Deionized Water
410×320×420 410×400×420 410×400×420
15 20 20
Main Body (Including 1 set of cartridges) + TDS Pen + Accessory Bag Main Body (Including 1 set of cartridges) + TDS Pen + Accessory Bag Main Body (Including 1 set of cartridges) + TDS Pen + Accessory Bag
120 72 72
AC110-220V, 50/60Hz AC110-220V, 50/60Hz AC110-220V, 50/60Hz
>13-17.5MΩ.cm >13-17.5MΩ.cm >13-17.5MΩ.cm
0.057-0.077μs/cm 0.057-0.077μs/cm 0.057-0.077μs/cm
<0.1cfu/ml (with terminal filter) <0.1cfu/ml (with terminal filter) <0.1cfu/ml (with terminal filter)
Particle (>0.2μm)<1/ml (with terminal filter) Particle (>0.2μm)<1/ml (with terminal filter) Particle (>0.2μm)<1/ml (with terminal filter)


NOTE : *The feed water quality will influence the pure water´s quality and cartridges´ life-span.

**PF : polypropylene spun fiber, AC:active carbon, RO : Reverse Osmosis, DI : ion exchange. ***All the specifications are tested under the situation:feed water´s TDS = 200 ppm, 25°C, 50psi and 15% recovery rate.



PURE WATER SUPPLY SYSTEM 100 SERIES


This system can be combined with any brand's water purification system to supply pure water for specific equipment and it is easy to install and maintain. It has Independent power control and it can be run automatically according to the liquid level of the tank. Independent power control and automatic operation, easy to install, use and maintain. Integrate level control, pressure pump, buffer tank and inlet valves together. It is unnecessary to connect to the circuit of pure water main-body. It can run automatically according to liquid lever of the tank. Optional UV lamp module, to restrain bacteria's increase and reduce TOC.


Spesification


Model BPWS-101 BPWS-102
Shape & Volume of tank Roundness : 100, 200 L Square :80,120,200 L Roundness : 500, 1000, 2000 L Square : 200 L
Specifications Of Pump
Volume of Buffer Tank 12 L 1 L
Vertical self-priming height 2 meters 2 meters
The Rated Stop Pressure 0.45 Mpa ± 0.4 Mpa 0.3 Mpa ± 0.4 Mpa, 0.35 Mpa ± 0.4 Mpa
Max Pressure / Pump Lift About 0.8 Mpa / 80 meters About 0.3 Mpa / 30 meters, About 0.35 Mpa / 35 meters



LABORATORY WATER PURIFICATION SYSTEM 100 SERIES


Laboratory water purification system uses double stage reverse osmosis technology. It produces double stage RO water, Deionised, EDI and ultrapure water. These systems have 3 way on-line water quality sensor, multiple alarm with unique design and it has easy-to-replace cartridges pack unit Double stage reverse osmosis technology.

Built-in 5.8 liters PE tank and 10 liters airtight plastic pressure water tank. Built-in 1st stage RO pump,2nd stage RO pump and circulating sanitizing pump. Unique design and easy-to-replace cartridges pack unit. Data storage and RS 232/USB communication port. 3 way on-line water quality sensor, multiple alarm. Life-span of cartridges' display and alarm. System circulation function, system sterilization procedure. The graphic display clearly indicates all system's parameters. From water quality to knowing when it is time to change the purification pack, you'll see at a glance what is need. For ease-of-use, the main purification technologies are contained in an innovative all-inone pack that mean you can change it in just a couple of minutes. The system requires no special installation, connect the system to your tap water supply it's ready to use.


SPESIFICATIONS


Model BPWS-101 BPWS-102
Shape & Volume of tank Roundness : 100, 200 L Square :80,120,200 L Roundness : 500, 1000, 2000 L Square : 200 L
Specifications Of Pump
Volume of Buffer Tank 12 L 1 L
Vertical self-priming height 2 meters 2 meters
The Rated Stop Pressure 0.45 Mpa ± 0.4 Mpa 0.3 Mpa ± 0.4 Mpa, 0.35 Mpa ± 0.4 Mpa
Max Pressure / Pump Lift About 0.8 Mpa / 80 meters About 0.3 Mpa / 30 meters,
About 0.35 Mpa / 35 meters


Model BLPS-101 BLPS-102 BLPS-103 BLPS-104
Feed Water Requirements
Water Inlet Tap water Tap water Tap water Tap water
Temperature 5-45°C 5-45°C 5-45°C 5-45°C
Pressure 1.0-4.0 Kgf/cm² 1.0-4.0 Kgf/cm² 1.0-4.0 Kgf/cm² 1.0-4.0 Kgf/cm²
Output 12 L/hrs at 25°C