Brand : Thermo Scientific™,Biolabs Scientific,Merck Millipore,Sartorius,Evoqua
Stok : In Stock
BASIC WATER PURIFICATION SYSTEM 100 SERIES
This basic series is ideal for wide range of applications. It produces RO,
Deionized water and Ultrapure water. The organic rejection rate is greater than 99% using reverse osmosis. The resistivity reaches up to 18.2MΩ.cm which completely meets the highest grade I standard.
SPESIFICATION
Model | BBPS-101 | BBPS-102 | BBPS-103 | BBPS-104 |
---|---|---|---|---|
Feed Water Requirements* | ||||
Water Inlet | Tap water: TDS < 200 ppm (Extra pretreatment filter is recommended,if TDS > 200ppm) | Tap water: TDS < 200 ppm (Extra Pretreatment Filter is Recommended,if TDS > 200 ppm) | Tap water: TDS < 200 ppm (Extra pretreatment filter is recommended,if TDS > 200ppm) | Tap water: TDS< 200 ppm (Extra pretreatment filter is recommended,if TDS> 200 ppm) |
Temperature | 5-45°C | 5-45°C | 5-45°C | 5-45°C |
Pressure | 1.0-4.0Kgf/cm² | 1.0-4.0Kgf/cm² | 1.0-4.0Kgf/cm² | 1.0-4.0Kgf/cm² |
Flow Procedure** | PF+AC+RO+AC | PF+AC+RO+AC | PF+AC+RO+AC | PF+AC+RO+AC |
RO Water Quality | ||||
Ion Rejection Rate | 96% - 99% (New RO membrane) | 96% - 99% (New RO membrane) | 96% - 99% (New RO membrane) | 96% - 99% (New RO membrane) |
Organic Rejection Rate | > 99 % (when MW > 200 Dalton) | > 99 % (when MW > 200 Dalton) | > 99 % (when MW > 200 Dalton) | > 99 % (when MW > 200 Dalton) |
Particles and Bacteria Rejection Rate | > 99% | > 99% | > 99% | > 99% |
Output(25°C)**** | 15 L/hrs | 30 L/hrs | 45 L/hrs | 15 L/hrs |
Pure Water Outlet | RO water | RO water | RO water | RO water |
Dimension LxWxH (mm) | 410×320×420 | 410×320×420 | 410×320×420 | 410×400×420 |
Weight (Kg) | 15 | 15 | 15 | 20 |
Main Body (Including 1 set of cartridges) + TDSpen + Accessory Bag | Main Body (Including 1 set of cartridges) + TDSpen + accessory bag | Main Body (Including 1 set of cartridges) + TDSpen + accessory bag | Main Body (Including1 set of cartridges) + built-in10 liters tank + TDS pen+ accessory bag | |
Standard Configuration | ||||
Power Consumption (W) | 72 | 72 | 120 | 72 |
Power Supply | AC110 - 220V, 50/60 Hz | AC110 - 220V, 50/60 Hz | AC110 - 220V, 50/60 Hz | AC110 - 220V, 50/60 Hz |
Deionized Water Quality | - | - | - | - |
Resistivity | - | - | - | - |
Conductivity | - | - | - | - |
Bacteria | - | - | - | - |
Particle (> 0.2μm) | - | - | - | - |
BBPS-105 | BBPS-106 | BBPS-107 | BBPS-108 |
---|---|---|---|
Tap Water : TDS < 200 ppm (Extra pretreatment filter is recommended, if TDS > 200ppm) | Tap water: TDS < 200 ppm (Extra pretreatment filter is recommended, if TDS > 200ppm) | Tap Water : TDS < 200 ppm (Extra pretreatment filter is recommended, if TDS > 200ppm) | Tap Water : TDS < 200 ppm (Extra pretreatment filter is recommended, if TDS > 200ppm) |
5-45°C | 5-45°C | 5-45°C | 5-45°C |
1.0-4.0Kgf/cm² | 1.0-4.0Kgf/cm² | 1.0-4.0Kgf/cm² | 1.0-4.0Kgf/cm² |
PF+AC+RO+AC | PF+AC+RO+AC | PF+AC+RO+DI | PF+AC+RO+DI |
96% - 99% (New RO membrane) | 96% - 99% (New RO membrane) | 96% - 99% (New RO membrane) | 96% - 99% (New RO membrane) |
> 99 % (when MW >200 Dalton) | > 99 % (when MW>200 Dalton) | > 99 % (when MW > 200 Dalton) | > 99 % (when MW > 200 Dalton) |
> 99 % | > 99 % | > 99 % | > 99 % |
30 L/hrs | 45 L/hrs | 15 L/hrs | 30 L/hrs |
RO water | RO water | RO and Deionized Water | RO and Deionized Water |
410 × 400 × 420 | 410 × 400 × 420 | 410 × 320 × 420 | 410 × 320 × 420 |
20 | 20 | 15 | 15 |
Main Body (Including 1 set of cartridges)+ built-in 10liters tank + TDS Pen+ accessory bag | Main body (Including 1 set of cartridges)+ built-in 10liters tank + TDS pen+ accessory bag | Main body (Including 1 set of cartridges) + TDS pen+ Accessory Bag | Main body (Including 1 set of cartridges) +TDS pen+ accessory bag |
72 | 120 | 72 | 72 |
AC110-220V, 50/60Hz | AC110-220V, 50/60Hz | AC110-220V, 50/60Hz | AC110-220V, 50/60Hz |
- | - | - | >13-17.5MΩ.cm |
- | - | - | 0.057-0.077μs/cm |
- | - | - | <0.1cfu/ml (with terminal filter) |
- | - | - | Particle (>0.2μm)<1/ml (with terminalfilter) |
BBPS-109 | BBPS-110 | BBPS-111 |
---|---|---|
Tap Water : TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200ppm) | Tap Water : TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200ppm) | Tap Water : TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200ppm) |
5-45°C | 5-45°C | 5-45°C |
1.0-4.0Kgf/cm² | 1.0-4.0Kgf/cm² | 1.0-4.0Kgf/cm² |
PF+AC+RO+DI | PF+AC+RO+DI | PF+AC+RO+DI |
96%-99%(New RO membrane) | 96%-99%(New RO membrane) | 96%-99%(New RO membrane) |
>99% (when MW>200 Dalton) | >99% (when MW>200 Dalton) | >99% (when MW>200 Dalton) |
>99% | >99% | >99% |
45 L/hrs | 15 L/hrs | 30 L/hrs |
RO and Deionized Water | RO and Deionized Water | RO and Deionized Water |
410×320×420 | 410×400×420 | 410×400×420 |
15 | 20 | 20 |
Main Body (Including 1 set of cartridges) + TDS Pen + Accessory Bag | Main Body (Including 1 set of cartridges) + TDS Pen + Accessory Bag | Main Body (Including 1 set of cartridges) + TDS Pen + Accessory Bag |
120 | 72 | 72 |
AC110-220V, 50/60Hz | AC110-220V, 50/60Hz | AC110-220V, 50/60Hz |
>13-17.5MΩ.cm | >13-17.5MΩ.cm | >13-17.5MΩ.cm |
0.057-0.077μs/cm | 0.057-0.077μs/cm | 0.057-0.077μs/cm |
<0.1cfu/ml (with terminal filter) | <0.1cfu/ml (with terminal filter) | <0.1cfu/ml (with terminal filter) |
Particle (>0.2μm)<1/ml (with terminal filter) | Particle (>0.2μm)<1/ml (with terminal filter) | Particle (>0.2μm)<1/ml (with terminal filter) |
NOTE : *The feed water quality will influence the pure water´s quality and cartridges´ life-span.
**PF : polypropylene spun fiber, AC:active carbon, RO : Reverse Osmosis, DI : ion exchange. ***All the specifications are tested under the situation:feed water´s TDS = 200 ppm, 25°C, 50psi and 15% recovery rate.
PURE WATER SUPPLY SYSTEM 100 SERIES
This system can be combined with any brand's water purification system to supply pure water for specific equipment and it is easy to install and maintain. It has Independent power control and it can be run automatically according to the liquid level of the tank. Independent power control and automatic operation, easy to install, use and maintain. Integrate level control, pressure pump, buffer tank and inlet valves together. It is unnecessary to connect to the circuit of pure water main-body. It can run automatically according to liquid lever of the tank. Optional UV lamp module, to restrain bacteria's increase and reduce TOC.
Spesification
Model | BPWS-101 | BPWS-102 |
---|---|---|
Shape & Volume of tank | Roundness : 100, 200 L Square :80,120,200 L | Roundness : 500, 1000, 2000 L Square : 200 L |
Specifications Of Pump | ||
Volume of Buffer Tank | 12 L | 1 L |
Vertical self-priming height | 2 meters | 2 meters |
The Rated Stop Pressure | 0.45 Mpa ± 0.4 Mpa | 0.3 Mpa ± 0.4 Mpa, 0.35 Mpa ± 0.4 Mpa |
Max Pressure / Pump Lift | About 0.8 Mpa / 80 meters | About 0.3 Mpa / 30 meters, About 0.35 Mpa / 35 meters |
LABORATORY WATER PURIFICATION SYSTEM 100 SERIES
Laboratory water purification system uses double stage reverse osmosis technology. It produces double stage RO water, Deionised, EDI and ultrapure water. These systems have 3 way on-line water quality sensor, multiple alarm with unique design and it has easy-to-replace cartridges pack unit Double stage reverse osmosis technology.
Built-in 5.8 liters PE tank and 10 liters airtight plastic pressure water tank. Built-in 1st stage RO pump,2nd stage RO pump and circulating sanitizing pump. Unique design and easy-to-replace cartridges pack unit. Data storage and RS 232/USB communication port. 3 way on-line water quality sensor, multiple alarm. Life-span of cartridges' display and alarm. System circulation function, system sterilization procedure. The graphic display clearly indicates all system's parameters. From water quality to knowing when it is time to change the purification pack, you'll see at a glance what is need. For ease-of-use, the main purification technologies are contained in an innovative all-inone pack that mean you can change it in just a couple of minutes. The system requires no special installation, connect the system to your tap water supply it's ready to use.
SPESIFICATIONS
Model | BPWS-101 | BPWS-102 |
---|---|---|
Shape & Volume of tank | Roundness : 100, 200 L Square :80,120,200 L | Roundness : 500, 1000, 2000 L Square : 200 L |
Specifications Of Pump | ||
Volume of Buffer Tank | 12 L | 1 L |
Vertical self-priming height | 2 meters | 2 meters |
The Rated Stop Pressure | 0.45 Mpa ± 0.4 Mpa | 0.3 Mpa ± 0.4 Mpa, 0.35 Mpa ± 0.4 Mpa |
Max Pressure / Pump Lift | About 0.8 Mpa / 80 meters |
About 0.3 Mpa / 30 meters, About 0.35 Mpa / 35 meters |
Model | BLPS-101 | BLPS-102 | BLPS-103 | BLPS-104 |
---|---|---|---|---|
Feed Water Requirements | ||||
Water Inlet | Tap water | Tap water | Tap water | Tap water |
Temperature | 5-45°C | 5-45°C | 5-45°C | 5-45°C |
Pressure | 1.0-4.0 Kgf/cm² | 1.0-4.0 Kgf/cm² | 1.0-4.0 Kgf/cm² | 1.0-4.0 Kgf/cm² |
Output | 12 L/hrs at 25°C |